Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Appl Radiat Isot ; 201: 110987, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37660500

RESUMO

A method for absolute measurements of the 225Ac activity in equilibrium with its progeny was developed. Measurements were performed using the triple-to-double coincidence ratio (TDCR) method in two different TDCR counters. The activity concentration of an 225Ac solution was determined and the solution was sent to the SIR system for a comparison. The half-life of 225Ac was determined by one of the TDCR counters and found to be 9.9150(63) days.

2.
Appl Radiat Isot ; 197: 110829, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37119706

RESUMO

The activity of the 177Lu solution has been measured by means of the CIEMAT/NIST efficiency tracing method. This result has been compared to the previous obtained results received from 4πß(LS)-γ coincidence and anticoincidence counting. The activities determined with various methods have been found to be consistent. The decay curve of the 177Lu solution has been followed in the TDCR counter to determine the half-life of this isotope. The half-life has been separately determined for double and triple coincidence events. The arithmetic mean value of these two results has been found to be T1/2 = 6.6489(52) d.

3.
Appl Radiat Isot ; 164: 109231, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32554122

RESUMO

Activity measurements of 3H, 241Am and 60Co solutions were performed to compare digital coincidence modules used at PTB and POLATOM for TDCR and 4πß(LS)-γ coincidence counting. The activities determined with various coincidence modules connected in parallel to the same counter at PTB were found to be consistent. Observed discrepancies caused by differences in the coincidence resolving time did not exceed 0.14%. Accidental coincidences simulated by a frequency generator were registered, and the coincidence resolving time was determined.

4.
Appl Radiat Isot ; 159: 109081, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32068144

RESUMO

Application of a new coincidence module using the pulse-mixing method in the 4π(LS)-γ coincidence system with TDCR detector in the beta channel (TDCRG) is presented. The pulse-mixing method extended for the TDCR system with gamma channel was compared with the classical coincidence method where the coincidence resolving time is introduced. The characteristics of the resolving and dead time of the above two methods were investigated. The level of accidental coincidences in the system was determined. The new developed coincidence module was validated by activity measurement of a set of 51Cr, 54Mn, 60Co, 65Zn, 85Sr and 134Cs standards.

5.
Appl Radiat Isot ; 134: 385-390, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29248210

RESUMO

An international key comparison, identifier CCRI(II)-K2.Ge-68, has been performed. The National Institute of Standards and Technology (NIST) served as the pilot laboratory, distributing aliquots of a 68Ge/68Ga solution. Results for the activity concentration, CA, of 68Ge at a reference date of 12h00 UTC 14 November 2014 were submitted by 17 laboratories, encompassing many variants of coincidence methods and liquid-scintillation counting methods. The first use of 4π(Cherenkov)ß-γ coincidence and anticoincidence methods in an international comparison is reported. One participant reported results by secondary methods only. Two results, both utilizing pure liquid-scintillation methods, were identified as outliers. Evaluation using the Power-Moderated Mean method results in a proposed Comparison Reference Value (CRV) of 621.7(11)kBqg-1, based on 14 results. The degrees of equivalence and their associated uncertainties are evaluated for each participant. Several participants submitted 3.6mL ampoules to the BIPM to link the comparison to the International Reference System (SIR) which may lead to the evaluation of a Key Comparison Reference Value and associated degrees of equivalence.

6.
Appl Radiat Isot ; 134: 126-130, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29102162

RESUMO

The aim of the work was to develop new radioactive standard sources based on epoxy resins. The optimal proportions of the components and the homogeneity of the matrices were determined. The activity of multigamma sources prepared in Marinelli beakers was determined with reference to the National Standard of Radionuclides Activity in Poland. The difference of radionuclides activity values determined using calibrated gamma spectrometer and the activity of standard solutions used are in most cases significantly lower than measurement uncertainty limits. Sources production method and quality control procedure have been developed.

7.
Appl Radiat Isot ; 134: 380-384, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29032880

RESUMO

A bilateral comparison between ENEA-INMRI (Italy) and NCBJ RC POLATOM (Poland) of 131I-solution activity measurements was organized in the year 2015 and piloted by POLATOM, which provided the sources for the comparison. The 131I master solution was standardized independently at both institutes by using Liquid Scintillation Counting and ionization chamber techniques. The 131I master solution was then sent by POLATOM to the BIPM International Reference System (SIR). The comparison was registered as an EURAMET.RI(II)-K2.I-131 key comparison allowing the ENEA-INMRI result to enter in the SIR database.

8.
Radiat Prot Dosimetry ; 168(3): 293-9, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25977349

RESUMO

A new large-volume metal reference standard has been developed. The intended use is for calibration of free-release radioactivity measurement systems and is made up of cast iron tubes placed inside a box of the size of a Euro-pallet (80 × 120 cm). The tubes contain certified activity concentrations of (60)Co (0.290 ± 0.006 Bq g(-1)) and (110m)Ag (3.05 ± 0.09 Bq g(-1)) (reference date: 30 September 2013). They were produced using centrifugal casting from a smelt into which (60)Co was first added and then one piece of neutron irradiated silver wire was progressively diluted. The iron castings were machined to the desirable dimensions. The final material consists of 12 iron tubes of 20 cm outer diameter, 17.6 cm inner diameter, 40 cm length/height and 245.9 kg total mass. This paper describes the reference standard and the process of determining the reference activity values.


Assuntos
Radioisótopos de Cobalto/análise , Monitoramento de Radiação/métodos , Resíduos Radioativos/análise , Prata/análise , Gerenciamento de Resíduos/normas , Humanos , Padrões de Referência
9.
Appl Radiat Isot ; 87: 19-23, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24331858

RESUMO

Standardization of (153)Sm by 4π(LS)-γ coincidence and anticoincidence counting and the CIEMAT/NIST method in three LS-counters is presented. This short half-life radionuclide is applied in tumor therapy and bone pain palliation. A simplified disintegration scheme of (153)Sm was applied in the calculation of the counting efficiency. Standard uncertainties of 0.4% for the (153)Sm measurements by the 4π(LS)-γ coincidence and anticoincidence techniques and 0.7% by the C/N method were evaluated, respectively. An agreement of the standardization results by both methods within the respective uncertainties was obtained. The half-life of (153)Sm of (1.92895±0.00024) days was determined during one month of measurements and correction for europium isotope impurities by the C/N method in the TriCarb 2910 LS-counter.


Assuntos
Samário/análise , Meia-Vida , Humanos , Padrões de Referência , Samário/farmacocinética , Samário/normas , Soluções , Incerteza
10.
Appl Radiat Isot ; 68(7-8): 1278-81, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-19945882

RESUMO

The Radioisotope Centre (RC) has organized for the first time in Polish hospitals a comparison of activity measurements of (99)Tc(m) and (131)I. From the 58 Polish hospitals invited, 37 participated in the comparison. Each participant got about 4 mL of (99)Tc(m) eluate and two (131)I capsules, low- and high-activity. Sources were standardized in the RC before dispatch using a 4pi ionization chamber calibrated by standard solutions. Participants used their own radionuclide calibrators. The measurement results were evaluated using the E(n) criterion and the z'-score. From all 118 measurement results received from participants, 75 results (64%) lay within +/-5% of the RC value, and 99 results (84%) lay within +/-10.0%.


Assuntos
Hospitais/normas , Radioisótopos do Iodo/análise , Tecnécio/análise , Calibragem , Laboratórios Hospitalares/normas , Variações Dependentes do Observador , Polônia , Radioisótopos/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...